Iron remover WFG-130 serves to remove dissolved water (bivalent) iron, manganese and hydrogen sulphide. Automatic operation of the system provides an electronic control unit Autotrol 268FA / 742 (France). The filter media used Manganese Greensand. Restoration of the filter layer (regeneration) is carried out automatically with a solution of potassium permanganate (potassium permanganate), for which a special container. The refresh rate is regulated by a timer that is set to the ECU. Factory setting regeneration time - two in the morning (time can be changed on customer's request). The room must be possible to drain waste water into the sewage system and the socket for connecting the adapter.
Specifications
Size column (tank) |
330 х 1372 mm |
Filling |
70 liters of Manganese Greensand catalyzer |
Regeneration |
Counterfow |
Counter type |
Timer |
Dynamic presure |
2,5 – 8,0 bar |
Temperature |
2 – 40о С |
Productivity |
0,8 – 1,5m3/h |
Water per regeneration |
550 l |
Duration of regeneration |
124 minutes |
KMnO4 consumption per regeneration |
140 – 180g |
Input/Output |
¾ - 1¼ inch |
Power |
220 V, 50Hz |
Adapter |
12 V |